missing translation for 'onlineSavingsMsg'
Learn More

Hanna Instruments™ Benchtop pH/mV Meter with 0.01 Resolution

Features automatic calibration to 1 or 2 points with 5 preprogrammed buffers. Hanna Instruments™ Benchtop pH/mV Meter with 0.01 Resolution displays pH and mV readings simultaneously and comes complete with an electrode, probe, buffers, electrolyte, cleaning solution and probe holder.

Brand:  Hanna Instruments™ HI-2211

Additional Details : Weight : 0.01000kg

Product Code. 11682220

  • 7095.00 SEK / Each


Estimated Shipment
18-03-2019
Add to basket

Description

Description

With the HI2211, operation is simplified to calibration, mode selection (pH or mV), and a Last Stored Reading feature. The mV mode is used with an optional ORP electrode that is used to check the oxidation or reduction potentials of a solution. The mV mode of the HI2211 is also useful in checking the offset and slope of the pH electrode, which is helpful in knowing if the probe is functioning correctly.

  • Easy to use with simple buttons and a large, clear display with stability indicator
  • Temperature Compensation: Automatic or manual from -9.9 to 120°C
  • Measurement Recall: Press the MEM button to store a reading, and recall it anytime by pressing MR
  • Separate inputs for a universal BNC pH electrode and thermistor temperature probe
  • High accuracy (0.5°C) temperature probe for precise temperature compensation
  • Automatic calibration to 1 or 2 points using the 5 preprogrammed buffers (4.01, 6.86, 7.01, 9.18, and 10.01)
  • mV mode can be used with a variety of ORP electrodes
  • HI1131B High Temperature (HT) glass body, double junction, refillable pH electrode with indicating sensor
  • Specifications

    Specifications

    LCD
    0 to 50°C
    2 years (probe: 6 months)
    ±0.2 (±399.9 mV), ±1 (±2000 mV)
    Automatic, with five memorized buffer values
    240 x 182 x 74mm (9.4 x 7.1 x 2.9 in.)
    -2.00 to 16.00
    High Temperature glass (electrode), Stainless Steel (temperature probe)
    12 VDC adapter
    ±399.9, ±2000
    Automatic or manual, -9.9 to 120°C
    −9.9 to 120°C
    ±0.01
    ±0.5°C, ±1°C outside
    1 or 2 points
    0.01
    HI1131B pH electrode, HI7662 temperature probe, HI76404N electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI7082 electrolyte solution, HI700601 cleaning solution sachet, 12 VDC adapter, and instructions
    HI1131B pH electrode (glass body, double junction, refillable, with an indicating sensor), HI7662 temperature probe (stainless steel)
    Max. 95%
    Videos