Läs mer
Thermo Scientific™ Polyacrylamide Desalting Columns, 6K MWCO, 10 mL
Handla allt Thermo Scientific ProdukterBeskrivning
Thermo Scientific™ Pierce Polyacrylamide Desalting Columns are ready-to-use, disposable, gel-filtration columns for separating proteins and other macromolecules from low molecular-weight buffer salts and reagents.
Highlights:
Formats: pre-packed 5mL and 10mL gravity-flow columns (1.8K and 6K MWCO only) and 0.7mL microcentrifuge columns (7K MWCO only)
Resin type: porous, beaded polyacrylamide
Bead size: 90 to 180μm dia. (6K and 7K resins); 45 to 90μm dia. (1.8K resin)
Flow rate: up to 2.5mL/min (fast compared to other desalting resins)
Chemical stability: compatible with water, salt solutions, many organic solvents and alkaline or acidic conditions
Mechanical stability: medium rigidity compared to other gel-filtration resins
Heat stability: resin is autoclavable dry or in solution at a neutral pH for 30 minutes at 120°C without affecting its chromatographic properties
Item-Specific Features:
- 1.8K MWCO resin (5mL column only) recovers all peptides and proteins larger than 1800 daltons with high efficiency; only salts and very small compounds (less than 100 MW) are removed fully
- 6K MWCO resin (5mL and 10mL columns only) recovers proteins larger than 6000 daltons with high efficiency; salts and small compounds (less than 1000 MW) are removed fully
- 7K MWCO resin (0.7mL spin column only) recovers proteins larger than 7000 daltons with high efficiency; salts and small compounds (less than 1000 MW) are removed fully
Includes:
Pre-packed columns with top and bottom caps
Recommended for:
Removing salts from protein solutions; Removing phenol from nucleic acid preparations; Separating excess crosslinker from conjugate preparations; Removing excess derivatizing agents from modified proteins; Removing unreacted dye from fluorescent antibodies; Removing free radiolabel from labeled proteins; Exchanging one buffer for another
Specifikationer
Specifikationer
| Produkttyp | Desalting Column |
| Innehåll och lagring | Upon receipt store at room temperature or 4°C. Product shipped at ambient temperature. |
| Formatera | Gravity Flow Column |
| Reningsmål | Buffer Exchange, Protein |
| Kolumntyp | Size-exclusion, Polyacrylamide Resin |
| MWCO | 6.0 kDa |
| Disponibel | Single-use |
| Kvantitet | 5 Columns |
| Volym (metrisk) | 2.5 mL |
Genom att klicka på Skicka bekräftar du att du kan bli kontaktad av Fisher Scientific angående feedbacken du har lämnat i detta formulär. Vi kommer inte att dela din information för andra ändamål. All kontaktinformation som tillhandahålls ska också underhållas i enlighet med vår Sekretesspolicy.