Perform susceptibility testing of Streptococcus species with this FDA cleared, convenient plate including Tigecycline.

Perform susceptibility testing of Streptococcus species with Thermo Scientific™ Sensititre™ Streptococcus STP6F AST Plate. This plate is FDA-cleared for automated or manual reading of Streptococcus species using the Thermo Scientific™ Sensititre™ ARIS™ 2X ID/AST System, Thermo Scientific™ Sensititre™ OptiRead System, or Sensititre™ manual platforms, including the Thermo Scientific™ Sensititre™ Vizion™ System for maximum versatility.

Eliminate offline tests with a full range of antimicrobials, including Tigecycline, with the Sensititre Streptococcus STP6F AST Plate. 

  • Individual packaging allows laboratories to test one isolate at a time
  • Test 20 antimicrobials on a single AST plate for cost-effective results
  • True MIC results provide better resistance tracking
  • Extended shelf life and room-temperature storage eliminate inventory control concerns

Not all products are available for sale in all territories. Please inquire.

VersaTREK™ and Sensititre™ products are now part of the Thermo Scientific brand.

TRUSTED_SUSTAINABILITY

Specifikationer

0,5 McFarland Standard MHB (Part No. T346205)
Antimikrobiella medel Various
Typ av buljong MHB w/ LHB (Part No. CP114)
Beskrivning Sensititre Streptococcus species MIC Plate
Antibiotikakod Various
Produkttyp AST Plate
Testtyp Minimum Inhibitory Concentration (MIC)
För användning med (applikation) All Streptococcus sp.
Inkubationsförhållanden 34-36°C O2
Inkubationstid 20-24 hr
Isolerar per platta 1
Antal per förpackning 10
Förpackningstyp Box
Kvantitet 10/Förpackning
Läsalternativ Autoread or manual
Överför volym 100µL
Volym per brunn 100 μL
Art Streptococcus species
Visa mer Visa mindre
Produkttitel
Välj ett problem