Thermo Scientific™ SRS Pro Solvent Recycling System

Produktkod. 10659405 Handla allt Thermo Scientific Produkter
Klicka för att se tillgängliga alternativ
:
SDG Pro degasser
Denna artikel kan inte returneras. Se returpolicy

Produktkod. 10659405

Brand: Thermo Scientific™ 66001010

This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
Se alternativa produkter

Denna artikel kan inte returneras. Se returpolicy

Innehåller

Software

Kräver

Personal computer (data system) running Microsoft™ Windows™ 98/2000/XP/Vista™ (32) with one free USB port.

Reduce mobile phase consumption by up to 90%

  • Continuously monitors the output signal of the chromatographic detector, recycling the mobile phase to the solvent reservoir when the baseline is below a certain preset threshold
  • Easy-to-use software is provided to configure system parameters, perform on-line monitoring and audit trail facilities
  • No power adapter is required as the solvent saver is powered directly from the chromatography data system PC through a USB connection
  • Recycles the mobile phase only if switched on: in case of power failure the valve remains in the waste position and the mobile phase in the reservoir remains uncontaminated
  • Analog input allows unipolar or bipolar operation of the device within a range of ±1V with an analog-to-digital converter
  • TTL/contact closure for the device can be configured as start, auto-zero or valve position control input

Operational Principle

  • If the input signal level exceeds this threshold value, the SRS Pro redirects the eluent flow to waste (1), taking account of the transport time from the detector to the switching valve
  • When the signal returns below the threshold (2), the SRS Pro again waits for the transport delay and then switches the mobile phase back to the reservoir
  • If the input signal level exceeds this threshold value, the SRS Pro redirects the eluent flow to waste, taking account of the transport time from the detector to the switching valve
  • When the signal returns below the threshold, the SRS Pro again waits for the transport delay and then switches the mobile phase back to the reservoir
  • Autosampler injection marker connected to the SRS Pro may ensure the zeroing of signal input at the moment of injection

TRUSTED_SUSTAINABILITY
Korrigering av produktinnehåll

Din input är viktig för oss. Fyll i det här formuläret för att ge feedback relaterad till innehållet på denna produkt.

Produkttitel

Genom att klicka på Skicka bekräftar du att du kan bli kontaktad av Fisher Scientific angående feedbacken du har lämnat i detta formulär. Vi kommer inte att dela din information för andra ändamål. All kontaktinformation som tillhandahålls ska också underhållas i enlighet med vår Sekretesspolicy.

Tack! Din feedback har skickats. Fisher Scientific arbetar alltid för att förbättra vårt innehåll åt dig. Vi uppskattar din feedback.