HPLC Columns

HPLC Columns
- (1)
- (9)
- (281)
- (570)
- (1)
- (57)
- (3)
- (776)
- (1)
- (61)
- (29)
- (8)
- (594)
- (152)
- (36)
- (6)
- (5)
- (1)
- (5)
- (14)
- (537)
- (11)
- (2)
- (1)
- (30)
- (6)
- (17)
- (1)
- (5)
- (29)
- (7)
- (1)
- (2)
- (5)
- (14)
- (5)
- (4)
- (2)
- (10)
- (100)
- (2)
- (1)
- (204)
- (1)
- (1)
- (2)
- (3)
- (125)
- (678)
- (1)
- (1)
- (146)
- (1)
- (2)
- (31)
- (8)
- (83)
- (382)
- (1)
- (106)
- (2)
- (272)
- (28)
- (755)
- (2)
- (2)
- (92)
- (2)
- (11)
- (1)
- (10)
- (35)
- (1)
- (21)
- (14)
- (5)
- (23)
- (27)
- (96)
- (299)
- (41)
- (8)
- (8)
- (4)
- (37)
- (39)
- (17)
- (196)
- (10)
- (6)
- (1)
- (690)
- (2)
- (1)
- (50)
- (2)
- (1,523)
- (10)
- (2)
- (44)
- (3)
- (20)
- (6)
- (5)
- (17)
- (1)
- (642)
- (2)
- (2)
- (3)
- (63)
- (107)
- (444)
- (213)
- (224)
- (106)
- (13)
- (601)
- (5)
- (68)
- (16)
- (5)
- (8)
- (6)
- (88)
- (164)
- (5)
- (14)
- (197)
- (1)
- (10)
- (2)
- (14)
- (104)
- (6)
- (2)
- (11)
- (2)
- (1)
- (9)
- (39)
- (120)
- (35)
- (12)
- (171)
- (2)
- (1)
- (2)
- (13)
- (178)
- (48)
- (11)
- (99)
- (2)
- (8)
- (2,089)
- (9)
- (21)
- (7)
- (10)
- (8)
- (1)
- (83)
- (11)
- (47)
- (4)
- (4)
- (4)

Thermo Scientific™ Hypersil GOLD™ C18 Selectivity HPLC Columns
SureTRACE
Supporting your traceability needs through proactive availability of certificates and change notifications.
Learn More

Supporting your traceability needs through proactive availability of certificates and change notifications.
Learn More
Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients
Thermo Scientific™ Hypersil™ ODS C18 Columns
Use as a general purpose C18 phase for acidic and neutral analytes.
Pore Size | 120 Ă… |
---|---|
Carbon Load | 10% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 170 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypersil™ BDS C18 Columns
Use as a robust, general-purpose column for a wide range of applications in QC/QA labs.
Carbon Load | 11% |
---|---|
Stationary Phase | C18 |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L1 |
Thermo Scientific™ BetaSil™ Silica HPLC Columns, 5μm Particle Size
Experience a powerful column for separating non-polar and moderately polar compounds based on 100Ă… high purity silica and designed for small molecule analysis.
Pore Size | 100 Ă… |
---|---|
Particle Size | 5 ÎĽm |
Stationary Phase | Silica |
Temperature | 35°C |
Phase | Normal Phase |
Packing Material | Spherical, Fully Porous Silica |
Column Type | Normal Phase |
Surface Area | 310 m²/g |
USP Type | L3 |
Thermo Scientific™ Hypersil™ PREP ODS C18 HPLC Columns
Perfect for routine workflows, our Hypersil PREP ODS preparative LC column is a general purpose C18 used in a broad range of USP L1 applications.
Pore Size | 130 Ă… |
---|---|
Carbon Load | 10% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous Silica |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 195 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypersil™ PREP HS C18 HPLC Columns
Maximize retention and loading with Hypersil PREP HS C18 prep LC reversed phase columns which offers high loading capacity and suitable for USP-L1 Applications.
Pore Size | 100 Ă… |
---|---|
Carbon Load | 15% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 350 m²/g |
USP Type | L1 |
Thermo Scientific™ μPAC™ Neo HPLC Columns
Learn more about your proteome samples with Thermo Scientific™ μPAC™ Neo HPLC columns.
Pore Size | 100 to 300 Ă… |
---|---|
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Silicon Chip |
pH | 1.5 to 7 |
Max. Pressure | 6526 psi (450 bar) |
Thermo Scientific™ Acclaim™ 120 C18 Columns
Use these high-efficiency reversed phase C18 columns for maximum resolution in a wide variety of applications.
Pore Size | 120 Ă… |
---|---|
Carbon Load | 18% |
Stationary Phase | C18 |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 300 m²/g |
USP Type | L1 |
Thermo Scientific™ ProPac™ 3R SAX 3 μm HPLC Columns
Get the performance you need with ProPac™ 3R SAX HPLC columns. Suitable for charge variant separations and recommended for therapeutic proteins, mAbs, ADCs, and AAVs.
Pore Size | Nonporous |
---|---|
Particle Size | 3 ÎĽm |
Stationary Phase | Proprietary |
Temperature | Ambient to 60°C |
Phase | Strong Anion Exchange |
Packing Material | Monodisperse Polymer Resin |
Column Type | Ion Exchange |
pH | 2 to 12 |
Technique | Bio-LC |
Max. Pressure | 4500 psi (310 bar) |
Product Line | ProPac |
Column Format | Analytical Column |
Thermo Scientific™ HyPURITY™ ADVANCE™ HPLC Columns, 5μm Particle Size
Use this specialty C8 column for separating compounds showing poor peak shape with traditional alkyl bonded phases.
Particle Size | 5 ÎĽm |
---|---|
Carbon Load | 9% |
Stationary Phase | C8 |
Phase | Reversed Phase |
Packing Material | Silica |
Column Type | Reversed Phase |
Surface Area | 200 m²/g |
USP Type | L7 |
Thermo Scientific™ Hypersil GOLD™ VANQUISH™ C18 UHPLC Columns
Obtain exceptional peak shape and high resolution for fast UHPLC high-pressure, high-throughput applications using generic gradients on Vanquish UHPLC and LC/MS systems.
Pore Size | 175 Ă… |
---|---|
Stationary Phase | C18 Selectivity |
Temperature | 60°C |
Phase | Reversed Phase |
For Use With | LC/MS |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 220 m²/g |
Column Format | Analytical Column |
Particle Size | 1.9 ÎĽm |
Carbon Load | 11% |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Diameter (Metric) | 2.1 mm |
pH | 1 to 11 |
Technique | Bio-LC |
Product Line | Hypersil GOLD |
USP Type | L1 |
Thermo Scientific™ ProPac™ Elite WCX HPLC Column
This column provides consistent separations of therapeutic proteins including monoclonal antibodies, antibody drug conjugates, biosimilars and charge variants.
Pore Size | Nonporous |
---|---|
Stationary Phase | Carboxylate |
Temperature | 10°C to 60°C |
Phase | Ion Exchange |
Column Type | Ion Exchange |
Green Features | Responsibly packaged |
Max. Pressure | 4500 psi (310 bar) |
Column Format | Analytical Column |
Particle Size | 5 ÎĽm |
Packing Material | Nonporous DVB Particles with Hydrophilic Coating |
Mobile Phase Compatibility | Recommended: Goods Buffers and NaCl. Minimum 20 mM salt required. Do not rinse with pure DI H2O |
pH | 2 to 12 |
Technique | Bio-LC |
Product Line | ProPac |
Thermo Scientific™ Acclaim™ HILIC-10 HPLC Columns
Use this HILIC column to retain and separate highly polar molecules that are unretained by reversed-phase chromatography.
Pore Size | 120 Ă… |
---|---|
Carbon Load | 8% |
Stationary Phase | Proprietary |
Temperature | 70°C |
Phase | HILIC |
For Use With | LC/MS |
Endcapped | Yes |
Column Type | HILIC |
pH | 2 to 8 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Syncronis™ C18 HPLC Columns
Robust separations with highly pure, high surface area silica that is double endcapped Syncronis C18 preparative HPLC columns with inertness toward basic compounds.
Pore Size | 100 Ă… |
---|---|
Particle Size | 5 ÎĽm |
Carbon Load | 16% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 320 m²/g |
USP Type | L1 |
Hamilton™ Hamilton™ RCX™ RCX-10 Ion Exchange HPLC Column, 7 μm, 4.6 mm x 250 mm
Column Format: Analytical Column; Pore Size: 100 Ă…; Column Phase: Ion Exchange