UserName
A Heritage of Innovation
At Cytiva, we envision a world in which access to life-changing therapies transforms human health.
With a rich heritage dating back hundreds of years, Cytiva brings a wealth of technical expertise and talent, a broad and deep portfolio, and exceptional service to help researchers and biopharma advance therapeutics at every stage from discovery to delivery.
We supply the tools and support our customers need to work better, faster, and safer, leading to the delivery of transformative medicines to patients. Our combined portfolio includes well-recognized names such as ÄKTA™, Amersham™, HyClone™, MabSelect™, Sentino™, Sera-Mag™, and Whatman™.
It began with a question: What if we could have more transparency into the environmental impact of our products? Now, the first 30 products from Cytiva’s filtration product line have recently received ACT labels — providing clear, third-party verified information of the impact these products have on the environment.
Cytiva is the first vendor to have syringe filters scored through the ACT labeling process. We are proud to provide this transparency to our customers and are excited to see the response from the industry.
The idea behind the Research Matters program is simple: For every purchase of any product from Cytiva’s laboratory research consumables portfolio, including Mab-Select™ chromatography resins, Whatman™ and Cytiva (formerly Pall Lab) lab filtration products, Sera-Mag™ Select reagents, Amersham™ nitrocellulose membranes, and selected HyClone™ cell culture products, one US dollar will be donated to the Breast Cancer Research Foundation (BCRF).
Pall Life Sciences and Cytiva have united under the Cytiva name.
With a shared mission to advance therapeutics from discovery to delivery, combining our organizations just made sense. With both Pall and Cytiva bringing a rich heritage dating back hundreds of years, we can now offer our expertise and portfolio of products and services together to better support every customer.
Use for desalting and buffer exchange, as well as removal of low-molecular weight compounds. Cytiva Life Sciences™ Disposable PD-10 Desalting Columns provide fast, high-recovery.
Covers a wide range of laboratory applications and is frequently used for clarifying liquids. Whatman™ Qualitative Filter Paper: Grade 1 Circles are widely used standard grade filter papers for routine applications with medium retention and flow rates.
| Thickness (Metric) | 180 μm |
|---|---|
| Flow Rate | 57mL/min. (water) |
| Particle Retention | >11 μm |
| Basis Weight | 87 g/m2 |
| Format | Disc |
| Airflow Rate | 13sec./100mL/sq. in. |
| Grade | Grade 1 |
| Material | Cellulose |
| Porosity | Medium |
| Filtration Speed | 150 sec. |
| For Use With (Application) | A widely used standard grade filter paper for routine applications with medium retention and flow rate. It covers a wide range of laboratory applications and is frequently used for clarifying liquids. |
Recognized standard in laboratories worldwide for isolation of human lymphocytes from peripheral blood. Cytiva™ Ficoll-Paque™ PLUS Media maintains the viability and a representative distribution of B and T lymphocytes.
| Content And Storage | 4–30°C |
|---|---|
| Form | Liquid |
| Product Type | Centrifugation Media |
| Color | Colorless to Slightly Yellow |
| Endotoxin Level | < 0.12 EU/mL |
| Shelf Life | 3 years |
| For Use With (Application) | Cell Isolation |
| Sterility | Sterile |
| Density | 1.078 g/mL |
Creates a hydrophobic filter that can replace separatory funnel in some applications. Whatman™ 1PS Disposable Phase Separating Paper is impregnated with stable silicone to allow solvent phases to pass through while retaining aqueous phases.
| Type | Separator Paper |
|---|---|
| Material | Fiberglass/Silicone |
| For Use With (Application) | Liquid phase separation |
Served as the basis filter for EPA standard for the toxicity characteristic leaching procedure. Whatman™ Binder-Free Glass Microfiber Filters GF/F Circles offers an extremely high loading capacity and flow rate.
| Particle Retention | 0.7 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | Whatman Grade GF/F filter from Cytiva's business is manufactured from pure borosilicate glass. GF/F offers very fine particle retention and good loading capacity and flow rate. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/F |
| Material | Borosilicate Glass |
| For Use With (Application) | Recommended for DNA binding and purification.Very effective in filtering finely precipitated proteins.Can be used in conjunction with GF/D as a prefilter for the successful clarification of extremely ‘difficult’ biochemical solutions and fluids and nucl |
| Thickness (Metric) | 420 μm |
| Flow Rate | 19 sec./100mL/in.2 |
| Type | Filter for TCLP Test Use |
| Format | Disc |
| Thickness (English) | 0.016 in. |
| Autoclavable | Autoclavable |
| Waterflow Rate | 41 mL/min |
Recommended for majority of routine applications, this membrane is manufactured under strictly controlled conditions. Whatman™ Type WCN Cellulose Nitrate Membranes narrow pore size distribution for improved surface capture and analysis.
| Color | White |
|---|---|
| Material | Cellulose Nitrate |
| Autoclavable | Autoclavable |
Combines high loading capacity with fine particle retention. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A are ideal for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.
| Particle Retention | 1.6 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | GE’s Whatman Grade GF/A glass microfiber filters feature fine retention. GF/A filters are suitable for water quality parameter measurement and air filtration applications. |
| Temperature (Metric) Max | 500°C |
| Quantity | 100 Pieces |
| Grade | Grade GF/A |
| Material | Borosilicate Glass |
| For Use With (Application) | Used for high-efficiency general purpose laboratory filtration, including water pollution monitoring of effluents, for filtration of water, foodstuff analyses, protein filtration, and radioimmunoassay of weak β emitters. |
| Thickness (Metric) | 260 μm |
| Flow Rate | 13 sec./100mL |
| Type | Fine Retention Filter |
| Format | Disc |
| Thickness (English) | 0.01 in. |
| Waterflow Rate | 143 mL/min |
Use as a high sensitivity reagent for chemiluminescent Western blotting detection. Cytiva Life Sciences™ Amersham™ ECL Select™ Western Blotting Detection Reagent provides highly intense signal output, for detection of medium to very low protein levels.
Use for rapid and efficient purification of DNA and oligonucleotides (>10-mer) in less than 15 minutes by gravity flow. Cytiva Life Sciences™ illustra™ NAP™ Columns are disposable columns prepacked with Sephadex™ G-25 DNA Grade
| Includes | Complete step-by-step protocol identifying the fixed volumes needed for equilibration, washing and sample elution |
|---|---|
| Product Type | NAP-25 |
| For Use With (Application) | Rapid and efficient purification of DNA and Oligonucleotides |
Whatman™ Mixed Cellulose Ester Membrane Filters are biologically inert and offers high degree of internal surface area for greater product adsorption.
| Material | MCE |
|---|---|
| Autoclavable | Autoclavable |
| Sterility | Sterile |
Pre-mixed, pre-dispensed reaction beads optimized for performing standard PCR amplifications. Cytiva Lifescience™ illustra™ PuReTaq Ready-To-Go™ PCR Beads are stable at ambient temperature.
| Quantity | 1 Kit |
|---|---|
| For Use With (Application) | Standard PCR |
For separation of cells, subcellular particles, and larger viruses (down to approx. 70S) under gentle conditions that preserve viability and morphological integrity. Cytiva™ Percoll™ Centrifugation Media Percoll is composed of colloidal silica coated with polyvinylpyrrolidone (PVP).
| Viscosity | 15cP |
|---|---|
| Content And Storage | 4–30°C |
| Form | Liquid |
| Product Type | Centrifugation Media |
| Color | Colorless to Slightly Yellow |
| pH | 8.5 to 9.5 |
| Shelf Life | 5 years |
| For Use With (Application) | Cell Isolation |
| Density | 1.135 g/mL |
| Osmolality | < 25 mOsm/kg |
Functions as a prefilter when used with GF/B microfiber filters. Whatman™ Binder-Free Glass Microfiber Prefilters, Grade GF/D provide efficient membrane protection, especially during liquid scintillation counting.
| Particle Retention | 2.7 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | GE’s Whatman Grade GF/D fine membrane filters are thick and offer good loading capacity. GF/D can also function as a prefilter when used with GF/B, and it comes in many sizes to fit most filter holders. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/D |
| Material | Borosilicate Glass |
| Thickness (Metric) | 675 μm |
| Flow Rate | 2.6 s/100mL/in2 |
| Type | Prefilter |
| Basis Weight | 121 g/m2 |
| Format | Disc |
| Thickness (English) | 0.02 in. |
| Autoclavable | Autoclavable |
| Waterflow Rate | 681 mL/min |
Purify histidine-tagged proteins directly from homogenized, unclarified cells. Cytiva HisTrap™ HP Prepacked Columns are prepacked with Ni Sepharose™ High Performance and designed for simple, high-resolution purification of histidine-tagged proteins by immobilized metal ion affinity chromatography (IMAC).
| Flow Rate | 4 mL/min. (1 mL), 5 mL/min. (5 mL) |
|---|---|
| Type | Pre-packed Column |
| Content And Storage | 4°C to 30°C |
| Description | HisTrap HP are nickel-charged IMAC columns for high resolution his-tagged protein purification with high binding capacity for maximized recovery. |
| Max. Operating Pressure | 5 bar (0.5 MPa, 70 psi) |
| pH Range | 3 to 12 |
| Material | Polypropylene |
| Support Type | 6% Highly Cross-linked Agarose |

This is a modal window.
Beginning of dialog window. Escape will cancel and close the window.
End of dialog window.
This is a modal window. This modal can be closed by pressing the Escape key or activating the close button.
Isolation and sequencing - cell culture - sample prep - purification - analysis.
Whatman capsule filters supporting cell culture include the Whatman Polycap TC for lysate pre-clearance and Whatman PolyVENT for bioreactor venting.
FAQs.
Modern brewers use a lot of science to deliver the quality and characteristics their customers expect.
Innovative solutions to unlock the potential of cells and genes. Stock up now and save big!
From method creation and sample loading to fraction collection and data analysis, we’ve thought about how to make your work easier at every step. Let ÄKTA start transform your manual purification workflow into a convenient automated solution that delivers reproducible results.
UNICORN start system control software is user-friendly, guiding you through each step in your purification, from creating a protocol and setting up your run to evaluating your results and creating a custom report. See how UNICORN start software saves you time and gives you valuable insight into your run or purification.
Modern brewers want their customers to receive consistent quality. This can be achieved by monitoring the brewing process with analytical methods.
We have solutions for degassing and clarifying wort or beer, detecting and analyzing microorganisms, and prefiltering samples prior to analysis by HPLC, NIR or UV/Vis spectroscopy.
We can guide you through your filter selection process, or you can request a sample. Simply complete the form below and we will be in touch.