UserName
A Heritage of Innovation
At Cytiva, we envision a world in which access to life-changing therapies transforms human health.
With a rich heritage dating back hundreds of years, Cytiva brings a wealth of technical expertise and talent, a broad and deep portfolio, and exceptional service to help researchers and biopharma advance therapeutics at every stage from discovery to delivery.
We supply the tools and support our customers need to work better, faster, and safer, leading to the delivery of transformative medicines to patients. Our combined portfolio includes well-recognized names such as ÄKTA™, Amersham™, HyClone™, MabSelect™, Sentino™, Sera-Mag™, and Whatman™.
It began with a question: What if we could have more transparency into the environmental impact of our products? Now, the first 30 products from Cytiva’s filtration product line have recently received ACT labels — providing clear, third-party verified information of the impact these products have on the environment.
Cytiva is the first vendor to have syringe filters scored through the ACT labeling process. We are proud to provide this transparency to our customers and are excited to see the response from the industry.
The idea behind the Research Matters program is simple: For every purchase of any product from Cytiva’s laboratory research consumables portfolio, including Mab-Select™ chromatography resins, Whatman™ and Cytiva (formerly Pall Lab) lab filtration products, Sera-Mag™ Select reagents, Amersham™ nitrocellulose membranes, and selected HyClone™ cell culture products, one US dollar will be donated to the Breast Cancer Research Foundation (BCRF).
Pall Life Sciences and Cytiva have united under the Cytiva name.
With a shared mission to advance therapeutics from discovery to delivery, combining our organizations just made sense. With both Pall and Cytiva bringing a rich heritage dating back hundreds of years, we can now offer our expertise and portfolio of products and services together to better support every customer.
Används för avsaltning och buffertbyte, samt avlägsnande av föreningar med låg molekylvikt. Cytiva Life Sciences™ Engångsavsaltningskolonner PD-10 ger snabb, hög återhämtning.
Använd detta mångsidiga nitrocellulosamembran för utmärkt bindningsaffinitet för små proteiner och peptider, såväl som nukleinsyror. Cytiva Amersham™ Protran™ NC Nitrocellulosamembran: Rullar erbjuder utmärkt känslighet, upplösning och låg bakgrund.
| Formatera | Rulla |
|---|---|
| Material | 100 % ren nitrocellulosa |
| För användning med (applikation) | Western blottar, dot-blot-analyser och andra protein- eller nukleinsyrametoder |
| Längd (metrisk) | 4 m |
| Innehåll och lagring | 15° till 30 °C |
|---|---|
| Certifikat och efterlevnad | Tillverkad under cGMP och ISO 9001 certifierade anläggningar |
| Steriliseringsmetod | 0,1μ m Sterilfiltrerad |
| Sterilitet | Sterila |
| Form | Vätska |
| Hållbarhet | 24 månader |
| pH | 7 till 7,6 |
| Regulatorisk status | RUO |
| Osmolalitet | 276 ±10mOsm/kg H2O |
| Endotoxinnivå | ≤0,025 EU/ml |
| Produkttyp | Dulbeccos fosfatbuffrade saltlösning |
| För användning med (applikation) | Fungerar som en spolnings-, transport- eller utspädningsvätska samtidigt som celltonicitet och livsduglighet bibehålls under en begränsad tidsperiod |
Kombinerar hög lastkapacitet med retention av fina partiklar. Whatman™ Bindemedelsfria glasmikrofiberfilter, klass GF/A är idealiska för gravimetrisk bestämning av luftburna partiklar, stackprovtagning och absorptionsmetoder för övervakning av luftföroreningar.
| Tjocklek (engelska) | 0,01 tum. |
|---|---|
| Tjocklek (metrisk) | 260μ m |
| Form | Cirkel |
| Partikelretention | 1.6μ m |
| Beskrivning | GE:s Whatman Klass GF/A glasmikrofiberfilter har fin retention. GF/A-filter är lämpliga för mätning av vattenkvalitetsparameter och luftfiltreringsapplikationer. |
| Typ | Fint retentionsfilter |
| Kvantitet | 100 stycken |
| Material | Borsilikatglas |
| Kvalitet | Betyg GF/A |
| Formatera | Skiva |
| Vattenflöde | 143 ml/min |
| Temperatur (metrisk) Max | 500 °C |
| Flödeshastighet | 13 sek./100 ml |
| Temperatur (engelska) Max. | 932 °F |
| För användning med (applikation) | Används för högeffektiv allmän laboratoriefiltrering, inklusive övervakning av vattenföroreningar av avloppsvatten, för filtrering av vatten, livsmedelsanalyser, proteinfiltrering och radioimmunanalys av svaga β-strålare. |
Erkänd standard i laboratorier över hela världen för isolering av humana lymfocyter från perifert blod. Cytiva™ Ficoll-Paque™ PLUS Media upprätthåller viabiliteten och en representativ fördelning av B- och T-lymfocyter.
| Densitet | 1.078 g/mL |
|---|---|
| Färg | Färglös till svagt gul |
| Innehåll och lagring | 4–30 °C |
| Sterilitet | Sterila |
| Form | Vätska |
| Hållbarhet | 3 år |
| Endotoxinnivå | < 0,12 EU/ml |
| Produkttyp | Centrifugeringsmedia |
| För användning med (applikation) | Cellisolering |
Används för att kontrollera/förstöra destruktiva mikroorganismer som bakterier
Möjliggör användning av mycket utspädda primära och sekundära antikroppar utan att minska känsligheten. Cytiva Lifescience™ Amersham™ ECL™ Prime Western Blotting Detection Reagent producerar hög signalintensitet och känslighet.
| Känslighet | ∼1 sid |
|---|---|
| Produkttyp | ECL Western Blot Detection Reagent |
| För användning med (applikation) | Känslig kvantitativ eller bekräftande Western Blot |
Rening av histidin-taggade proteiner direkt från homogeniserade, oklarifierade celler. Cytiva HisTrap™ HP färdigpackade kolonner är färdigpackade med Ni Sepharose™ Högpresterande och designad för enkel, högupplöst rening av histidin-taggade proteiner genom immobiliserad metalljonaffinitetskromatografi (IMAC).
| Innehåll och lagring | 4 °C till 30 °C |
|---|---|
| pH-intervall | 3 till 12 |
| Flödeshastighet | 4 ml/min. (1 ml), 5 ml/min. (5 ml) |
| Beskrivning | HisTrap HP är nickelladdade IMAC-kolonner för högupplöst his-taggad proteinrening med hög bindningskapacitet för maximerad återhämtning. |
| Typ | Färdigpackad kolonn |
| Material | Polypropen |
| Max. Driftstryck | 5 bar (0,5 MPa, 70 psi) |
| Typ av stöd | 6 % starkt tvärbunden agaros |
Highly species-specific anti-Mouse IgG. Cytiva Lifescience™ anti-Mouse IgG, peroxidase-linked species-specific whole antibody (from sheep) Secondary Antibody is designed for applications such as protein blotting, ELISA and immunocytochemistry.
| Antigen | IgG, Whole Molecule |
|---|---|
| Reningsmetod | Affinity Purified |
| Värd art | Sheep |
| Klassificering | Monoclonal |
| Primär eller sekundär | Secondary |
| Isotyp | IgG |
| Konjugera | HRP |
| Innehåll och lagring | 15° till 30 °C |
|---|---|
| Certifikat och efterlevnad | cGMP och ISO 9001:2000 Riktlinjer |
| Steriliseringsmetod | 0,1μ m Sterilfiltrerad |
| Form | Vätska |
| pH | 7,0 till 7,2 |
| Endotoxinnivå | =1.0EU/mL |
| Produkttyp | Fosfatbuffrad saltlösning (PBS) |
| Utan tillsatser | Inget kalcium,Inget magnesium,Utan fenolrött |
Minimera röran och kontaminering under spill. Whatman™ Benchkote materialet har ett högkvalitativt, slätt, absorberande lager av labbpapper som suger upp vätskespill. Ett andra laminerat polyetenskikt förhindrar genomströmning till arbetsytan.
| Mått (L x B) | 460 x 570mm |
|---|---|
| Material | Polyeten |
| Bredd (metrisk) | 570 mm |
| Produkttyp | Ytskydd |
| Längd (metrisk) | 460 mm |
Används för snabb och effektiv rening av DNA och oligonukleotider (> 10-mer) på mindre än 15 minuter genom gravitationsflöde. Cytiva Life Sciences™ illustra™ NAP™ Kolumner är engångskolonner förpackade med Sephadex™ G-25 DNA-kvalitet
| Produkttyp | NAP-5 |
|---|---|
| Inkluderar | Komplett steg-för-steg-protokoll som identifierar de fasta volymer som behövs för utjämning, tvättning och proveluering |
| För användning med (applikation) | Snabb och effektiv rening av DNA och oligonukleotider |
A highly species-specific anti-Rabbit IgG. Cytiva Lifescience™ anti-Rabbit IgG, peroxidase-linked species-specific whole antibody (from donkey) Secondary Antibody is used with Amersham™ ECL Western Blotting detection reagents.
| Antigen | IgG |
|---|---|
| Reningsmetod | Affinity Purified |
| Värd art | Donkey |
| Klassificering | Monoclonal |
| Primär eller sekundär | Secondary |
| Isotyp | IgG |
| Konjugera | HRP |
| Tjocklek (engelska) | 0,017 tum. |
|---|---|
| Kvalitet | 934-AH RTU |
| Vattenflöde | 341 ml/min |
| Temperatur (metrisk) Max | 550 °C |
| Tjocklek (metrisk) | 435μ m |
| Flödeshastighet | 47 sek./100 ml |
| Partikelretention | 1.5μ m |
| Temperatur (engelska) Max. | 1022 °F |
| Beskrivning | Vår Whatman glas mikrofiber filterpapper i kvalitet 934-AH RTU har förtvättats, torkats (eller antänts), kylts, torkats och vägts, vilket eliminerar de förbehandlingssteg som annars krävs enligt US EPA Laboratory Standard Method 2540 del |
| Typ | RTU-filter för analys av totala suspenderade ämnen |
| Kvantitet | 100 stycken |
| Material | Borsilikatglas |
| För användning med (applikation) | Övervakning av floder, sjöar och kustvatten |
Används för optimerad rening av histidinmärkta proteiner direkt från homogeniserade, oklarade celler genom immobiliserad metalljonaffinitetskromatografi (IMAC). Cytiva Life Sciences™ HisTrap™ FF Columns: 16 x 25 mm är en färdig att använda kolonn, förpackad med förladdat Ni Sepharose™ 6 Snabbt flöde.
| Innehåll och lagring | 4 °C till 30 °C, 20 % etanol |
|---|---|
| pH-intervall | 3 till 12 |
| Flödeshastighet | <20 ml/min. |
| Beskrivning | HisTrap FF är en kolonn som är klar att använda, färdigpackad med förladdad Ni Sepharose 6 Fast Flow för preparativ rening av histidin-taggade rekombinanta proteiner med immobiliserad metalljonaffinitetskromatografi (IMAC). |
| Typ | Färdigpackad kolonn |
| Material | Polypropen |
| Max. Driftstryck | 5 bar (0,5 MPa, 70 psi) |
| Typ av stöd | 6 % tvärbunden agaros |
| Diameter (engelska) Inre | 0,6 tum |
| Diameter (metrisk) Inre | 16 mm |

This is a modal window.
Beginning of dialog window. Escape will cancel and close the window.
End of dialog window.
This is a modal window. This modal can be closed by pressing the Escape key or activating the close button.
Isolation and sequencing - cell culture - sample prep - purification - analysis.
Whatman capsule filters supporting cell culture include the Whatman Polycap TC for lysate pre-clearance and Whatman PolyVENT for bioreactor venting.
FAQs.
Modern brewers use a lot of science to deliver the quality and characteristics their customers expect.
Explore advanced solutions for food processing, testing, and analysis. Enhance accuracy, quality, and efficiency with our selection of products. Promo code: 24137
From method creation and sample loading to fraction collection and data analysis, we’ve thought about how to make your work easier at every step. Let ÄKTA start transform your manual purification workflow into a convenient automated solution that delivers reproducible results.
UNICORN start system control software is user-friendly, guiding you through each step in your purification, from creating a protocol and setting up your run to evaluating your results and creating a custom report. See how UNICORN start software saves you time and gives you valuable insight into your run or purification.
Modern brewers want their customers to receive consistent quality. This can be achieved by monitoring the brewing process with analytical methods.
We have solutions for degassing and clarifying wort or beer, detecting and analyzing microorganisms, and prefiltering samples prior to analysis by HPLC, NIR or UV/Vis spectroscopy.
We can guide you through your filter selection process, or you can request a sample. Simply complete the form below and we will be in touch.