Chromatography Columns and Cartridges

Trajan™ HT8-PCB 8% Phenyl Capillary Columns

SGE GC column HT8 is a unique, high temperature phase designed for the analysis of polychlorinated biphenyl (PCB) congeners GC Capillary Column 60MX 0.25MM ID - HT8-PCB0.15UM

Thermo Scientific™ Hypersil Drop-In Guard Cartridges —C18, C8, C1, Silica

Convenient, economical, and effective protection for extending column lifetimes X4 10X4MM 10µM ODS

Thermo Scientific™ TraceGOLD TG-ALC1 GC Columns

Analyze blood alcohols with this ultra-low bleed column for enhanced sensitivity and reproducibility TG-ALC 1 30M X 0.53MM X 1.80µMID 0.32 length 30m film thickness 1.8um

Thermo Scientific™ BetaSil™ C18 Guard Cartridges

Economically extends HPLC column lifetime X4 10X3MM 5µM BETASIL C18 GUARD

Lenz Laborglasinstrumente™ Chromatographic Columns with Frit and NS Socket

Chromatographie-Säule m. Fritte P0, PTFE- Hahn, L. 200 mm, i.D. 10 mm, Hülse NS14/23

Thermo Scientific™ TracePLOT TG-BOND Q GC Columns

Achieve consistent, reproducible separation of CO2, methane and 02/N2/CO with the non-polar PLOT column with essentially no particle release. TG-BOND Q 30M X 0.53MM X 20µM

Thermo Scientific™ TracePLOT TG-BOND U GC Columns

For consistent, reproducible analysis of nonpolar and polar compounds, choose the polar PLOT column with essentially no particle release. TG-BOND U 30M X 0.53MM X 20µM

Thermo Scientific™ Shodex OHpak SB-G Guard Column

For use with HPLC columns. SHODEX OHPAK SB-G GUARD

Thermo Scientific™ TRACE™ TR-FAME GC Columns

For separation of cis/trans isomers and FAMEs with various degrees of unsaturation, choose this low-bleed, high-polarity column optimized for FAME analysis. TRACE TR-FAME GC COLUMN 25M 0.32

Thermo Scientific™ TraceGOLD TG-XLBMS GC Columns

Thermo Scientific™ TraceGOLD TG-XLBMS GC Columns offer a low polarity, low bleed column suitable for a wide range of applications. TG-XLBMS 30M X 0,32MM X 0,25µM

Thermo Scientific™ Fluophase™ PFP Javelin™ Guard Columns

Offer convenient, easy to use protection for analytical HPLC columns X4 20X2.1MM 5µM FLUOPHASE PFP

Thermo Scientific™ TraceGOLD TG-ALC Plus GC Column

Employ the most widely used MS phase in gas chromatography with the 5% phenyl phase Thermo Scientific™ TraceGOLD™ TG-ALC GC Column. GC COLUMN,TRACEGOLD TG-ALC Plus I,30mx0.53mmx3.0µm

GE Healthcare HiScreen™ Capto™ Adhere Impres Multimodal Chromatography Column

Ready-to-use column for method optimization and parameter screening x1 Prepacked column, HiScreen Capto adhere ImpRes, 4.7mL volume

Kinesis™ Omnifit™ Glass Columns for Low/Medium Pressure Liquid Chromatography

Standard aqueous system with a borosilicate glass chromatographic tube and a PTFE plunger Benchmark column Omnifit(R) with 2 x fixed endpiec

Trajan™ BPX Volatiles Column

SGE BPX Volatiles Column is a polar phase designed for EPA volatile organics analysis BPX-Volatiles GC Column 3µm 30M x 0.53MM

Trajan™ BP1/BP1 PONA Column

SGE GC column BP1 PONA is an industry standard non polar phase suitable for all routine analysis Capillary GC column BP1 general purpose, non-polar

Thermo Scientific™ TraceGOLD TG-1701MS GC Columns

Features a mix of cyano and phenyl groups for increased polarity and a different elution order relative to less polar columns. TG-1701MS 30M X 0.32MM X 0.50µM

Thermo Scientific™ TraceGOLD™ TG-624 and TG-624SilMS GC Columns

Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability. GC COLUMN, TRACEGOLD TG-624SilMS, 60mx0.32mmx1.8µm

Thermo Scientific™ TraceGOLD TG-5MS GC Columns

Employ the most widely used MS phase in gas chromatography with the 5% phenyl phase Thermo Scientific™ TraceGOLD™ TG-5MS GC Column. TG-5MS 15M X 0.32MM X 0.25µM

Thermo Scientific™ TraceGOLD™ TG-200MS GC Columns

Resolve compounds that phenyl and cyano phases cannot using a low-bleed GC column with an exceptionally inert phase. TG-200MS 30M X 0.32MM X 1µM

Thermo Scientific™ TRACE™ TR-5 GC Columns

Excellent starting columns for method development, Thermo Scientific™ TRACE™ TR-5 GC Columns are capable of performing most required separations. TRACE TR-5 30M 0,32MM 0,25µM

Thermo Scientific™ TraceGOLD TG-5SilMS GC Columns

Incorporates phenyl groups in the polymer backbone for improved thermal stability, reduced bleed and reduced susceptibility to oxidation. TG-5SILMS 30M X 0.32MM X 1µM

Thermo Scientific™ EASY-Spray™ Transfer Lines

Connect your nano or capillary column to your Thermo Scientific™ EASY-Spray™ source-equipped mass spectrometers more easily using EASY-Spray transfer lines.

EASY SPRAY EMITTER MICRO FLOW

Thermo Scientific™ TraceGOLD TG-35MS AMINE GC Columns

Utilizes a chemically altered tubing surface to reduce peak tailing and eliminates the need for column priming when analysing amines and other basic compounds. TG-35MS AMINE 30M X 0.32MM X 1µM

Thermo Scientific™ BetaSil™ Phenyl Guard Cartridges

Thermo Scientific™ BetaSil™ Phenyl Guard Cartridges are available in limited dimensions. Please contact Customer Service for more details. X4 10X4MM 5µM BETASIL PHENYL GUAR

Thermo Scientific™ TRACE™ TR-Wax GC Columns

Analyze a wide range of polar compounds with this low-bleed, general purpose, high polarity GC column. TRACE TR-WAX30M 0,25MM 0,25µM

Thermo Scientific™ TraceGOLD™ TG-WaxMS GC Columns with SafeGuard

Produce consistent results with this low-bleed, stable column produces. TG-5WAXMS GC 10M SG 30MX.25MMX.25µ

Thermo Scientific™ TRACE™ GC Columns for Drugs of Abuse

Analyze common drugs of abuse with these GC columns and achieve high performance, sensitivity and reproducibility. GC COLUMN TRACE TR-DOA5 FOR LABdrug testing and confirmation of THC 15m x 0.25mm

Thermo Scientific™ TraceGOLD™ TG-WaxMS GC Columns

Analyze FAMEs with excellent thermal stability using the Thermo Scientific™ TraceGOLD™ TG-WaxMS GC Column. TG-WAXMS 15M X 0.25MM X 0.25µM

  spinner