Manual Gas Tight Syringes
Manual Gas Tight Syringes
Gas tight syringes for manual injections on GC instruments; includes fixed-needle, removable-needle formats in various sizes, needle gauges, needle point styles, and terminations; includes zero dead-volume and headspace syringes.
- (19)
- (24)
- (51)
- (2)
- (1)
- (115)
- (29)
- (87)
- (6)
- (1)
- (3)
- (1)
- (1)
- (11)
- (1)
- (1)
- (4)
- (36)
- (1)
- (65)
- (15)
- (79)
- (52)
- (32)
- (80)
- (12)
- (63)
- (3)
- (1)
- (1)
- (4)
- (137)
- (1)
- (11)
- (1)
- (58)
- (28)
- (13)
- (11)
- (51)
- (10)
- (1)
- (12)
- (9)
- (23)
- (40)
- (5)
- (2)
- (3)
- (201)
- (11)
- (12)
- (2)
- (3)
- (9)
- (101)
- (288)
- (1)
- (8)
- (1)
- (1)
- (1)
- (1)
- (72)
- (8)
- (21)
- (246)
- (13)
- (1)
- (69)
- (10)
- (195)
- (1)
- (13)
- (2)
- (2)
- (1)
- (119)
- (137)
- (1)
- (48)
- (1)
- (2)
- (13)
- (1)
- (10)
- (42)
- (36)
- (74)
- (1)
- (1)
- (5)
- (6)
- (16)
- (66)
- (1)
- (1)
- (1)
- (2)
- (1)
- (4)
- (4)
- (9)
- (2)
- (16)
- (8)
- (1)
- (11)
- (6)
- (6)
- (1)
- (2)
- (12)
- (2)
- (1)
- (1)
- (19)
- (5)
- (1)
- (1)
- (2)
- (1)
- (3)
Filtered Search Results
Accuracy | ±1% |
---|---|
Product Type | Gastight Syringe |
Connection Type | Removable |
Quantity | Ea. |
Length (English) Needle | 1.96 in. |
For Use With (Application) | Suitable for gases or liquids for maximum inertness |
Volume (Metric) | 10 μL |
---|
SGE™ Gas Tight Syringe with Removable Needle
Ideal for sample storage, transportation and pressurizing samples prior to injection
Product Type | Analytical Syringe |
---|---|
Connection Type | Removable |
Quantity | Ea. |
Diameter (Metric) Outer Needle | 0.63 mm |
Needle Gauge | 23 G |
Diameter (English) Outer Needle | 0.024 in. |
Trajan™ Syringe with Valve
Ideal for sample storage and transportation or to pressurize sample prior to injection.
Hamilton™ 1700 and 1000 Series Gastight™ SampleLock™ Syringes, 22 Gauge
Hamilton SampleLock syringes allow you to collect, store, transport and analyze liquid or gaseous samples without the danger of evaporative loss or environmental contamination.
Needle Point Number | 2 |
---|---|
Quantity | Ea. |
Min. Temperature (English) | 50°F |
For Use With (Application) | To collect, store, transport and analyze liquid or gaseous samples without the danger of evaporative loss or environmental contamination |
Diameter (Metric) Inner Needle | 0.41 mm |
Product Type | General Purpose Syringe |
Connection Type | Sample Lock, Removable |
Needle Point Style | Sharp, Bevel, Curved, Non-coring |
Diameter (Metric) Outer Needle | 0.72 mm |
Length (English) Needle | 2 in. |
Autoclavable | Not Autoclavable |
Min. Temperature (Metric) | 10°C |
Needle Gauge | 22 G |
Diameter (English) Outer Needle | 0.02 in. |
Diameter (English) Inner Needle | 0.01 in. |
Trajan Scientific and Medical™ MicroVolume Syringes
Gives better performance and superior quality. Trajan Scientific and Medical MicroVolume Syringes has the knowledge and expertise that goes into manufacturing an SGE syringe.
Product Type | Removable Needle |
---|---|
Needle Point Style | Bevel |
Thermo Scientific™ Manual, Fixed Needle, Gas Tight Syringes for GC Instruments
Choose Thermo Scientific™ Fixed-Needle, Gas-Tight Syringes for manual accurate, reproducible GC sample introduction using an affixed needle and a plunger that creates a tight seal.
Thermo Scientific™ Fixed-Needle, Gas-Tight Syringes for GC Instruments
Choose Thermo Scientific™ Fixed-Needle, Gas-Tight Syringes for accurate, reproducible GC sample introduction using an affixed needle and a plunger that creates a tight seal.
Connection Type | Fixed |
---|
Thermo Scientific™ Luer-Tip, Gas-Tight Manual Syringes for GC Systems
Get a gas-tight syringe for manual injections. This syringe features a Luer-Tip connection and is available in a variety of sizes.
Thermo Scientific™ Male Luer-LOK Priming Syringes
Thermo Scientific™ Male Luer-LOK Priming Syringes offer easy, accurate and reproducible manual injections.
Thermo Scientific™ Removable-Needle Autosampler Syringes for GC Instruments
Thermo Scientific™ Removable-Needle Autosampler Syringes for GC Instruments are accurate and reproducible over a range of volumes.
Thermo Scientific™ TriPlus RSH Autosampler Fixed Needle Syringe, 100μL
Thermo Scientific™ TriPlus RSH Autosampler Fixed Needle Syringes are accurate and reproducible over a range of volumes.
Thermo Scientific™ TriPlus RSH Autosampler Fixed GT Needle Syringe
Thermo Scientific™ TriPlus RSH Autosampler Fixed GT Needle Syringes are accurate and reproducible over a range of volumes.
Connection Type | Fixed |
---|---|
Material | Stainless Steel (Needle),Stainless Steel (Plunger) |
Length (Metric) Needle | 57 mm |
Thermo Scientific™ GC Syringe for CTC
Thermo Scientific™ Gastight GC Syringes are accurate and reproducible over a range of volumes.
Hamilton™ 1000 Series Gastight™ Syringes: Luer Lock Syringes, TLL Termination
Mid-volume GASTIGHT syringe ideal for dispensing volumes from 100 μL up to 100 mL.
Needle Point Number | No Needle Included |
---|---|
Product Type | Gastight Syringe |
Quantity | Ea. |
For Use With (Application) | Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments |